INVONIC 2

Ultrasonic hybrid heat and cooling meter (DN15-100)

It is designed for installation in heating/cooling systems in residential, office and industrial premises where water is the heat/cold medium.

  • Liquid flow measurement using ultrasonic technology

  • High accuracy

  • For use in residential and industrial buildings

  • Heating and cooling energy measurement

  • MID DN15 - DN100

Illustration

INVONIC 2

Illustration

Ultrasonic hybrid heat and cooling meter (DN15-100)

  • Liquid flow measurement using ultrasonic technology


  • High accuracy


  • icon

    For use in residential and industrial buildings


  • Heating and cooling energy measurement


  • MID DN15 - DN100


  • Communication

    AMR interfaces, optional
    ● Wireless M-Bus 868 MHz (only on-board)● M-Bus● Modbus

  • Features

    ● Battery lifetime 15 + 1 years
    ● Metering archive: hourly, daily, monthly
    ● Temperature of conveying liquid: 5°C ... 130°C● Can be equipped with two outputs or pulse inputs

CHARACTERISTICS

  • OPTICAL INTERFACE

    WIntegrated into the front panel of calculator. It is designed
    for data reading via M-bus protocol and parameterization
    of the meter.

  • RADIO INTERFACE

    The internal radio provides data reading via WMBUS
    telegram: S1, T1 OMS mode.
    WMBUS telegram:
    ● Current total Energy
    ● Current flow
    ● Current date and time
    ● Accounting date information
    ● Error date

  • LCD INDICATOR

    „ ● The device is equipped with 8-digits LCD (Liquid CrystalDisplay) with special symbols to display parameters,measurement units and operation modes.„ ● The following information can be displayed:ƒ - integral and instantaneous measured parameters,ƒ - archive data and set day data,ƒ - device configuration information.„ ● Programmable LCD displaying parameters.

  • SPECIAL FEATURES

    ● Flexible meter configuration. Meter is delivered in user
    configuration mode with possibility to configure meter
    parameters and features as: units, mounting position,
    pulse inputs/outputs, e.t.c.
    ● Accuracy class 2● Nominal flow 0.6 I 1.0 / 1.5 / 2.5 / 3.5 / 6.0 / 10.0 / 15.0 /25.0 I 40.0 I 60.0 m3/h● Dynamic range up to Op/Qi= R 100/250● There is no need for straight segments for DN15 - DN50● Environmental class B● Protection class IP65/67/68● Nominal pressure PN16/25 bar● Maximum pressure loss P25 / P63● Temperature measurement Pt500, 0 °С ... 180 °С;● Temperature of conveying liquid: 5°C ... 130°C● Metering archive: hourly, daily, monthly● Battery lifetime 15 + 1 years● Power supply options: Battery/External● Mounting in any installation position● Can be equipped with two outputs or pulse inputs● Tariff functions

  • DATA LOGGER - HISTORY VALUES

    ● Every hour, day and month values of the measured
    parameters are stored in internal memory
    ● All data from archive can be read by means of the remote
    reading
    ● In addition data logger records of monthly parameters can
    be seen on the display
    ● Hours for archive records: 1480 hours● Days for archive records: 1130 days● Months for archive records: 36 months● Time of storage of all measured integral data, also without
    power supply to the electronic unit: at least 15 years

  • DATA REGISTRATION
    Hourly, daily and monthly parameter values

    ● Integrated energy● Integrated cooling energy● Integrated energy of tariff● Integrated volume of liquid● Integrated pulse value in pulse input 1/2● Maximum thermal power value for heating/cooling and
    date
    ● Maximum value of flow/return temperature of heat
    conveying liquid and date
    ● Minimum value of flow/return temperature of heat
    conveying liquid and date
    ● Minimum value of temperature difference and date● Average value of flow/return temperature of heat
    conveying liquid
    ● Operating time without an error● Total error code● Time when the flow rate exceeded 1,2 Qs● Time when the flow rate was less than Qi

  • POWER SUPPLY (depending on meter configuration)

    ● AA battery 3,6 V 2,4 Ah (Li-SOCl2) battery, operation time
    at least 15 + 1 years
    ● 12 ... 42 V DC or 12 ... 36 V 50 / 60Hz AC external power
    supply, used current 10 mA and back up battery AA 3,6 V
    (Li-SOCl2)
    ● 230 V (+ 10% - 30%) 50 I 60Hz AC power supply, current
    consumption is not more than 10 mA

Basic technical data

No. Q3 [m3/h] DN [mm] Length [mm] Connection
1 0.6 15 110
2 0.6 20 190 G1/flange
3 1 15 110
4 1 20 190 G1/flange
5 1.5 15 110
6 1.5 20 130 G1
7 1.5 20 190 G1/flange
8 2.5 20 130 G1
9 2.5 20 190 G1/flange
10 3.5 25 260 G 1¼ / flange
11 6.0 25 260 G 1¼ / flange
12 10.0 40 300 G2/flange
13 15.0 50 270 flange
14 25 65 300 flange
15 40 80 300 flange
16 60 100 360 flange

Technical data

Illustration

Perfection has no limits!


Experienced team

We have an extensive experience and successfully completed more than 10 000 projects.

Custom-tailored approach

We appreciate each client and consider all demands throughout our cooperation.

First-class product

We use modern technologies and advanced solutions to develop our products.

Have any questions?

Leave your phone number and we will contact you

Дякуємо!


Can't send form.

Please try again later.

Made with